Data cabinets, Cloakroom equipment

Free-standing cabinet RMA

Free-standing cabinet RMA

Welded cabinet with removable side panels and rear cover,
IP20, capacity 400 kg.

A universal cabinet for data and telecommunication purposes. Sufficient capacity for common applications, a large selection of sizes and options together with a wide selection of accessories and excellent development make it the best selling cabinet in our range.

RIGID CONSTRUCTION

RMA has a robust welded construction. High quality processing and the newest technologies ensure a perfect look of the cabinet.

FLEXIBLE DOOR OPENING

The hinge system allows the door to open almost 180°. The door can be easily removed and re-mounted to change the direction of opening.

TRITON HANDLES

We manufacture our own handles for the free-standing cabinets. By changing the plastic module (not included), a traditional  or semi-cylindrical lock insert can be used. Patent: PUV 2013-27443

ADJUSTABLE VERTICAL RAILS

Vertical 19” rails can be adjusted freely in any depth of the cabinet. This simplifies mounting of the device and configuration of connecting cables.

REMOVABLE SIDE PANELS AND REAR COVER

RMA has a welded frame and removable side panels. These are fixed as standard to the frame using a lock with the same key as the door and rear cover.

DOOR FOR FAN UNITS

With this cabinet type, it is possible to order a special metal door ready for mounting RAx-CH-X0x-X3 fan units. Further information is available in the section Active cooling.

BREAK-OUT BLANKING PANELS

Entry openings for cables in the rear part of the cabinet are covered with breakout-type blanking panels. It is possible to use a blanking panel with a brush in cable opening to avoid dust penetration. The plastic frame serves to protect cables from damage (both are parts of the cabinet supply).

OPENING FOR A FAN UNIT

A large opening covered with a breakout-type blanking panel enables mounting and removal of the Triton fan unit from outside of the cabinet without a need of using screws.

CASTORS, LEVELLING FEET

Prepared for mounting castors and levelling feet.

THE BACK SIDE OF THE CABINET

On the rear cover of the cabinet are two cable openings covered with breakout panels. One is at the top and one at the bottom of the rear cover. Other cable entries are on the ceiling and the base of the cabinet.

PERFORATED FRAME

The RMA cabinet has a perforated frame to ensure cooling air has access to the equipment inside. Cooling can be augmented by installing fan units.

EARTHING

All removable parts are interconnected and earthed according to the relevant standards.

FLEX FRAME

(for cabinet of 800 mm width) This system enables sliding vertical rails to be installed in a span of 19“, 21“ and 23“, just as needed for the equipment being used.

MIDDLE PAIR OF VERTICAL RAILS

For cabinets deeper than 800 mm a third pair of vertical rails is supplied. An open profile means that the middle rails do not limit installation of deeper devices.

Product variants

Supply includes:RMA double boxRMA double box
 
Key - rear and side panels 2x
Key - front door 4x
Key - back door 4x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
Safety hardened glass 4 mm thick
Steel sheet


RMA 42 U - double box(21 U + 20 U)

TypeABCDEOpenings for fanWeight gross (kg)Weight net (kg))maximum recommended load (kg)
 (mm)

RMA-42-A66-CAX-A12BAA

1970 1868 487 600 600 2 84,9 77,8
400

RMA-42-A68-CAX-A12BAA

1970 1868 487 600 800 2 97,5 89,2

RMA-42-A69-CAX-A12BAA

1970 1868 487 600 900 2 104,8 94,6

RMA-42-A61-CAX-A12BAA

1970 1868 487 600 1000 2 111,9 101,1

RMA-42-A86-CAX-A12BAA

1970 1868 687 800 600 2 100,0 91,3

RMA-42-A88-CAX-A12BAA

1970 1868 687 800 800 2 114,1 104,5

RMA-42-A89-CAX-A12BAA

1970 1868 687 800 900 2 126,0 113,1

RMA-42-A81-CAX-A12BAA

1970 1868 687 800 1000 2 133,9 120,5

RMA-45-A66–CAX–A1

2105 2003 487 600 600 3 83,0 75,8
Supply includes:RMA double boxRMA double box
 
Key - rear and side panels 2x
Key - front door 4x
Key - back door 4x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
Safety hardened glass 4 mm thick
Steel sheet


RMA 45 U - double box (22 U + 22 U)

TypeABCDEOpenings
for fan*
Weight
gross (kg)
Weight
net (kg)
maximum recommended load (kg)
 (mm)

RMA-45-A66-CAX-A12BAA

2105 2003 487 600 600 2 89,1 82,0
400

RMA-45-A68-CAX-A12BAA

2105 2003 487 600 800 2 103,4 95,0

RMA-45-A69-CAX-A12BAA

2105 2003 487 600 900 2 110,9 100,7

RMA-45-A61-CAX-A12BAA

2105 2003 487 600 1000 2 116,2 105,4

RMA-45-A86-CAX-A12BAA

2105 2003 687 800 600 2 105,5 96,8

RMA-45-A88-CAX-A12BAA

2105 2003 687 800 800 2 120,8 110,9

RMA-45-A89-CAX-A12BAA

2105 2003 687 800 900 2 130,4 117,4

RMA-45-A81-CAX-A12BAA

2105 2003 687 800 1000 2 137,3 124,1

RMA-45-A66–CAX–A1

2105 2003 487 600 600 3 83,0 75,8
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 600 x 600 mm
Safety hardened
glass 4 mm thick
Steel sheet



RMA 600 x 600

TypeABCDEOpenings for fanWeight gross
(kg)
Weight net
(kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A66–CAX–A1

770 668 487 600 600 1 40,3 33,5 400

RMA-18-A66–CAX–A1

900 798 487 600 600 1 44,1 37,5

RMA-22-A66–CAX–A1

1080 978 487 600 600 2 49,3 42,5

RMA-27-A66–CAX–A1

1300 1198 487 600 600 2 58,3 51,4

RMA-32-A66–CAX–A1

1525 1423 487 600 600 3 65,1 58,1

RMA-37-A66–CAX–A1

1750 1648 487 600 600 3 72,2 65,0

RMA-42-A66–CAX–A1

1970 1868 487 600 600 3 78,8 71,7

RMA-45-A66–CAX–A1

2105 2003 487 600 600 3 83,0 75,8

RMA-47-A66–CAX–A1

2194 2092 487 600 600 3 85,6 78,4

 

RMA-45-A66–CAX–A1

2105 2003 487 600 600 3 83,0 75,8
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 600 x 800 mm
Safety hardened
glass 4 mm thick
Steel sheet



RMA 600 x 800

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A68–CAX–A1

770 668 487 600 800 1 46,1 39,1 400

RMA-18-A68–CAX–A1

900 798 487 600 800 1 50,4 43,3

RMA-22-A68–CAX–A1

1080 978 487 600 800 2 56,1 49,1

RMA-27-A68–CAX–A1

1300 1198 487 600 800 2 66,1 58,9

RMA-32-A68–CAX–A1

1525 1423 487 600 800 3 73,7 66,4

RMA-37-A68–CAX–A1

1750 1648 487 600 800 3 81,5 74,1

RMA-42-A68–CAX–A1

1970 1868 487 600 800 3 88,9 81,5

RMA-45-A68–CAX–A1

2105 2003 487 600 800 3 93,5 86,0

RMA-47-A68–CAX–A1

2194 2092 487 600 800 3 96,4 88,9
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 600 x 900 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 600 x 900

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended load (kg)
 (mm)

RMA-15-A69–CAX–A1

770 668 487 600 900 1 49,7 42,9 400

RMA-18-A69–CAX–A1

900 798 487 600 900 1 54,4 47,5

RMA-22-A69–CAX–A1

1080 978 487 600 900 2 60,8 53,8

RMA-27-A69–CAX–A1

1300 1198 487 600 900 2 72,7 65,6

RMA-32-A69–CAX–A1

1525 1423 487 600 900 3 81,1 73,9

RMA-37-A69–CAX–A1

1750 1648 487 600 900 3 89,7 82,5

RMA-42-A69–CAX–A1

1970 1868 487 600 900 3 98,0 90,8

RMA-45-A69–CAX–A1

2105 2003 487 600 900 3 103,1 98,5

RMA-47-A69–CAX–A1

2194 2092 487 600 900 3 106,8 99,5
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 600 x 1000 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 600 x 1000

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A61–CAX–A1

770 668 487 600 1000 1 52,5 45,6 400

RMA-18-A61–CAX–A1

900 798 487 600 1000 1 57,5 50,5

RMA-22-A61–CAX–A1

1080 978 487 600 1000 2 64,1 57,1

RMA-27-A61–CAX–A1

1300 1198 487 600 1000 2 76,4 69,2

RMA-32-A61–CAX–A1

1525 1423 487 600 1000 3 85,2 78,0

RMA-37-A61–CAX–A1

1750 1648 487 600 1000 3 94,3 86,9

RMA-42-A61–CAX–A1

1970 1868 487 600 1000 3 102,9 95,6

RMA-45-A61–CAX–A1

2105 2003 487 600 1000 3 108,3 100,9

RMA-47-A61–CAX–A1

2194 2092 487 600 1000 3 111,8 104,4
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 600 x 1100 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 600 x 1100

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A60–CAX–A1

770 668 487 600 1100 1 61,0 49,5 400

RMA-18-A60–CAX–A1

900 798 487 600 1100 1 67,6 54,7

RMA-22-A60–CAX–A1

1080 978 487 600 1100 2 74,8 61,9

RMA-27-A60–CAX–A1

1300 1198 487 600 1100 2 84,0 70,9

RMA-32-A60–CAX–A1

1525 1423 487 600 1100 3 93,0 79,9

RMA-37-A60–CAX–A1

1750 1648 487 600 1100 3 102,2 89,0

RMA-42-A60–CAX–A1

1970 1868 487 600 1100 3 111,1 97,8

RMA-45-A60–CAX–A1

2105 2003 487 600 1100 3 116,6 103,3

RMA-47-A60–CAX–A1

2194 2092 487 600 1100 3 119,8 106,5
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 600 x 1200 mm
Safety hardened
glass 4 mm thick
Steel sheet





RMA S 600 x 1200

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A62–CAX–A1

770 668 487 600 1200 1 64,0 52,4 400

RMA-18-A62–CAX–A1

900 798 487 600 1200 1 69,4 57,8

RMA-22-A62–CAX–A1

1080 978 487 600 1200 2 76,9 65,3

RMA-27-A62–CAX–A1

1300 1198 487 600 1200 2 86,4 74,6

RMA-32-A62–CAX–A1

1525 1423 487 600 1200 3 95,8 84,0

RMA-37-A62–CAX–A1

1750 1648 487 600 1200 3 103,5 91,5

RMA-42-A62–CAX–A1

1970 1868 487 600 1200 3 114,7 102,7

RMA-45-A62–CAX–A1

2105 2003 487 600 1200 3 120,3 108,3

RMA-47-A62–CAX–A1

2194 2092 487 600 1200 3 123,7 111,7
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 800 x 600 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 800 x 600

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A86–CAX–A1

770 668 687 800 600 1 50,8 40,7 400

RMA-18-A86–CAX–A1

900 798 687 800 600 1 55,1 44,9

RMA-22-A86–CAX–A1

1080 978 687 800 600 2 60,9 50,6

RMA-27-A86–CAX–A1

1300 1198 687 800 600 2 70,5 60,1

RMA-32-A86–CAX–A1

1525 1423 687 800 600 3 78,2 67,7

RMA-37-A86–CAX–A1

1750 1648 687 800 600 3 86,0 75,3

RMA-42-A86–CAX–A1

1970 1868 687 800 600 3 93,5 82,8

RMA-45-A86–CAX–A1

2105 2003 687 800 600 3 98,0 87,3

RMA-47-A86–CAX–A1

2194 2092 687 800 600 3 101,0 90,2
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 800 x 800 mm
Safety hardened
glass 4 mm thick
Steel sheet



RMA 800 x 800

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A88–CAX–A1

770 668 687 800 800 1 58,5 48,3 400

RMA-18-A88–CAX–A1

900 798 687 800 800 1 63,2 53,0

RMA-22-A88–CAX–A1

1080 978 687 800 800 2 69,6 59,3

RMA-27-A88–CAX–A1

1300 1198 687 800 800 2 80,3 69,9

RMA-32-A88–CAX–A1

1525 1423 687 800 800 3 88,6 78,2

RMA-37-A88–CAX–A1

1750 1648 687 800 800 3 97,2 86,6

RMA-42-A88–CAX–A1

1970 1868 687 800 800 3 105,4 94,7

RMA-45-A88–CAX–A1

2105 2003 687 800 800 3 110,4 99,7

RMA-47-A88–CAX–A1

2194 2092 687 800 800 3 113,7 103,0
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 800 x 900 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 800 x 900

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg)
 (mm)

RMA-15-A89–CAX–A1

770 668 687 800 900 1 63,1 52,7 400

RMA-18-A89–CAX–A1

900 798 687 800 900 1 68,2 57,8

RMA-22-A89–CAX–A1

1080 978 687 800 900 2 75,2 64,7

RMA-27-A89–CAX–A1

1300 1198 687 800 900 2 87,6 77,0

RMA-32-A89–CAX–A1

1525 1423 687 800 900 3 96,9 86,2

RMA-37-A89–CAX–A1

1750 1648 687 800 900 3 106,3 95,5

RMA-42-A89–CAX–A1

1970 1868 687 800 900 3 115,4 104,5

RMA-45-A89–CAX–A1

2105 2003 687 800 900 3 121,0 110,0

RMA-47-A89–CAX–A1

2194 2092 687 800 900 3 124,9 113,9
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 800 x 1000 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 800 x 1000

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended load (kg)
 (mm)

RMA-15-A81–CAX–A1

770 668 687 800 1000 1 66,3 55,9 400

RMA-18-A81–CAX–A1

900 798 687 800 1000 1 71,7 61,2

RMA-22-A81–CAX–A1

1080 978 687 800 1000 2 78,9 68,4

RMA-27-A81–CAX–A1

1300 1198 687 800 1000 2 91,9 81,2

RMA-32-A81–CAX–A1

1525 1423 687 800 1000 3 101,5 90,8

RMA-37-A81–CAX–A1

1750 1648 687 800 1000 3 111,3 100,4

RMA-42-A81–CAX–A1

1970 1868 687 800 1000 3 120,9 110,0

RMA-45-A81–CAX–A1

2105 2003 687 800 1000 3 126,6 115,6

RMA-47-A81–CAX–A1

2194 2092 687 800 1000 3 130,5 119,5

 

Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 800 x 1100 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 800 x 1100

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended
load (kg
 (mm)

RMA-15-A80–CAX–A1

770 668 687 800 1100 1 77,6 63,8 400

RMA-18-A80–CAX–A1

900 798 687 800 1100 1 83,4 69,5

RMA-22-A80–CAX–A1

1080 978 687 800 1100 2 91,2 77,3

RMA-27-A80–CAX–A1

1300 1198 687 800 1100 2 100,9 86,9

RMA-32-A80–CAX–A1

1525 1423 687 800 1100 3 110,8 96,7

RMA-37-A80–CAX–A1

1750 1648 687 800 1100 3 120,8 106,5

RMA-42-A80–CAX–A1

1970 1868 687 800 1100 3 130,5 116,1

RMA-45-A80–CAX–A1

2105 2003 687 800 1100 3 136,4 122,0

RMA-47-A80–CAX–A1

2194 2092 687 800 1100 3 140,0 125,6
Supply includes:RMARMA
Key - rear and side panels 2x
Key - front door 2x
Captive nut M6 16x
Blanking panel with brush 1x
Frame for cable entry 1x
Adjustable feet 4x
Nut M10 4x

Material:
RMA 800 x 1200 mm
Safety hardened
glass 4 mm thick
Steel sheet


RMA 800 x 1200

TypeABCDEOpenings
for fan
Weight
gross (kg)
Weight
net (kg)
maximum recommended load (kg
 (mm)

RMA-15-A82–CAX–A1

770 668 687 800 1200 1 81,3 67,5 400

RMA-18-A82–CAX–A1

900 798 687 800 1200 1 86,8 73,0

RMA-22-A82–CAX–A1

1080 978 687 800 1200 2 95,2 81,3

RMA-27-A82–CAX–A1

1300 1198 687 800 1200 2 105,3 91,3

RMA-32-A82–CAX–A1

1525 1423 687 800 1200 3 115,5 101,4

RMA-37-A82–CAX–A1

1750 1648 687 800 1200 3 123,9 109,7

RMA-42-A82–CAX–A1

1970 1868 687 800 1200 3 136,0 121,6

RMA-45-A82–CAX–A1

2105 2003 687 800 1200 3 142,1 127,7

RMA-47-A82–CAX–A1

2194 2092 687 800 1200 3 145,8 131,4
  • 19“ free-standing cabinet with IP20 protection.
  • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm).
  • Cabinet construction:
    – Welded steel frame with removable side panels.
    – Single or double doors in variants fully-metal, perforated (80% air permeability) or glazed with safety tempered glass 4 mm. They can be on the front or back of the cabinet.
  • Max. permissible load of the door is 20 kg.
  • Min. thickness of the surface finish is 65 µm.
  • These cabinets are intended for installation data and telecommunication devices and their distribution systems.
  • The frame of the cabinet and all the removable parts (side and rear covers, doors…) are connected with earthing cables that have to be properly fixed and inserted into connectors during all the time when using the cabinet.
  • There is one M8 screw placed on the bottom part of the cabinet as an earthing main point.
  • Cable openings covered with breakout-type blanking panels are placed in the top and the bottom part of the cabinet.

OPERATION CONDITIONS

• Operation environment:
– Office
– The cabinet is not intended for outdoor installations and for installations in environment that can influence negatively the functionality of the cabinet and the mounted devices (e.g. environment with danger of explosion or humid and wet surroundings).

• Must be protected against:
– Mechanical damage.
– Improper handling.
– A different usage than the cabinet is intended for.

• Improper handling is especially:
– Overloading (maximum recommended load exceeding).
– Device installation that can influence negatively operation and function of the cabinet or the installed equipment.
– Change of the construction or design of the cabinet.

INSTALLATION OF THE CABINET

• To ensure the maximum recommended load, it is necessary to distribute the load equally.
• Place the cabinet on a flat floor and adjust any differences using the levelling feet.
• To avoid dust penetration in the case where cables lead through some of the cable openings, it may be sealed with a blanking panel with a brush or secured by a plastic frame (both are included in the delivery).

ENVIRONMENTAL PROTECTION

• All parts are made of recyclable materials and after decommissioning the cabinet, it must be disposed of according to relevant regulations

CERTIFICATE AND CONFORMITY

• This product is certified by ITI TÜV, certification number 06.140.501/r1, date 03/01/2013 and is fully in conformi-ty with ČSN EN 62208 ed.2:2012(EN 62208:2011).

Photogallery

RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA
RMA-42-L61-BAX-A1-MAA
RMA-42-L61-BAX-A1-MAA
RMA-42-L61-BAX-A1-MAA
RMA-42-L61-BAX-A1-MAA
RMA-42-L61-BAX-A1-MAA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
RMA-42-L61-BAX-A1-OZA
more pictures

Download

Certificate

Catalog

Write Us

Name

Report:
Control code
Captcha