Data cabinets, Cloakroom equipment

Server cabinet RDE

RDE

Welded server cabinet prepared for the installation of independent air-conditioning units, IP54, capacity 1800 kg.

Loading capacity 1800 kg

The RDE data cabinet has a reinforced construction and it is made of thicker material. Also 19“ vertical rails are designed for a higher loading capacity. A version with depth over 800 mm has a central pair of vertical rails as a standard solution.

Protection against dust and humidity IP54

All the doors and covers are equipped with a sealing that ensures protection against dust penetration and humidity. For more information see the section Active Cooling.

Wider body rails

Wider rails in the body of a cabinet are intended for an additional installation of 19“ power management panels that afterwards do not occupy space within the cabinet. Thanks to this smart solution it does not block sliding servers even within the 600 mm cabinet type.

Server cabinet with an IP54 protection

The RDE cabinets are primarly intended for an installation of servers and active devices parallelly with a Triton A/C units. Air conditioning unit is necessary to install only to data cabinets with a high IP protection for a correct function.

A/C units

It is possible to install the roof A/C unit model ETE on the RDE data cabinet to manage the temperature inside of the cabinet. For such installation a special adapter is required. Adapter must correspond with an A/C unit type and also with requested air flow direction (along side panels or front/rear). A proper A/C unit must be selected by following information about thermal heat output of installed equipment, surrounding temperature with respect to humidity inside of the data cabinet. Our specialists are at your disposal. When A/C unit is installed the IP protection rating lower down to IP20.

Cable entries

All cable entries must be properly sealed especially against the dust and humidity, which could in air-conditioned area start condensing and could also damage installed equipment. Furthermore it could start freezing inside of the A/C unit which can lead to its break down. A blanking panel with sealed cable grommets is part of the cabinet supply.

STRENGTHENED VERTICAL RAILS

Vertical rails are made from thicker material and differ from standard type thanks to its shape as well.

PLACING IN CABINET ROW

Cabinet RDE can be placed in the line with standard cabinets without any problem.

Product variants

Supply includes:RDE
Key - door 2x
Sealing strip  
nut M5 4x
Screw M5x12 4x
Set of captive nuts, screws M6,
plastic washers
16x
RAX-PB-X01-X1 1x

Material:

Safety hardened glass 4 mm thick
Steel shee


RDE width 600 mm

TypeABCDEWeight
gross (kg)
Weight
net (kg)
maximum
recommended load (kg)
 (mm)

RDE-42-A68-XCX-A1

1970 1868 487 600 800 127,0 118,7 1800

RDE-45-A68-XCX-A1

2105 2003 487 600 800 132,8 124,4

RDE-42-A61-XCX-A1

1970 1868 487 600 1000 144,7 133,9

RDE-45-A61-XCX-A1

2105 2003 487 600 1000 151,1 140,3

RDE-42-A62-XCX-A1

1970 1868 487 800 1200 160,5 147,2

RDE-45-A62-XCX-A1

2105 2003 487 800 1200 164,9 154,1
Supply includes:RDE
Key - door 2x
Sealing strip  
nut M5 4x
Screw M5x12 4x
Set of captive nuts, screws M6,
plastic washers
16x
RAX-PB-X01-X1 1x

Material:

Safety hardened glass 4 mm thick
Steel sheet


RDEwidth 800 mm

TypeABCDEWeight
gross (kg)
Weight
net (kg)
maximum
recommended load (kg)
 (mm)

RDE-42-A88-XCX-A1

1970 1868 687 800 800 157,0 147,4 1800

RDE-45-A88-XCX-A1

2105 2003 687 800 800 163,7 154,0

RDE-42-A81-XCX-A1

1970 1868 687 800 1000 177,8 164,4

RDE-45-A81-XCX-A1

2105 2003 687 800 1000 184,9 171,4

RDE-42-A82-XCX-A1

1970 1868 687 800 1200 195,2 179,2

RDE-45-A82-XCX-A1

2105 2003 687 800 1200 201,4 185,2
• 19‘‘ free-standing cabinet with IP54 protection
• Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm).
• Cabinet construction:
– Welded steel frame with removable side panels fixed by screws
– Single or double doors sealed by foam gasket in variants fully-metal or glazed with safety tempered glass 4mm. They can be on the front or back of the cabinet. To achieve needed protection the doors with 3-point locking system are standard for this model.
• Max. permissible load of the door is 20 kg.
• Min. thickness of the surface finish is 65 µm.
• These cabinets are intended for installation of data and telecommunication devices and their distribution systems.
• The frame of the cabinet and all the removable parts (side and rear covers, doors…) are bonded with patch cables that have to be properly fixed and inserted into connectors throughout the period of use of the cabinet.
• There is one M8 screw placed on the bottom part of the cabinet to connect the bonding.
• Cable openings placed in the top and bottom part of the cabinet are secured by dismountable blanking panels.

OPERATION CONDITIONS

• Operation environment:
– Industrial, office
– The cabinet is not intended for outdoor installations and for installations in environment that can influence negatively the functionality of the cabinet and the mounted devices (e.g. environment with danger of explosion)

• Must be protected against:
– Mechanical damage
– Improper handling
– A different usage than the cabinet is intended for

• Improper handling is especially:
– Overloading (maximum recommended load exceeding)
– Device installation that can influence negatively operation and function of the cabinet or the installed equipment
– Change of the construction or design of the cabinet

INSTALLATION OF THE CABINET

• To ensure the maximum recommended load, it is necessary to distribute the load equally.
• Place the cabinet on a flat floor and adjust any differences using the levelling feet.
• To avoid dust penetration in the case where cables lead through some of the cable openings, it may be sealed with a blanking panel with a brush or secured by a plastic frame (both are included in the delivery).

ENVIRONMENTAL PROTECTION

• All parts are made of recyclable materials and after decommissioning the cabinet, it must be disposed of according to relevant regulations.

CERTIFICATE AND CONFORMITY

• This product is fully in accordance with ČSN EN 62208 ed 2:2012.

Photogallery

more pictures

Download

Certificate

Catalog

Movie